| S. No. |
Particular |
Description |
| 1 |
Material |
Check out our Special Grade Stainless Steel Refractory Line Metal, designed with a robust thickness! It features a solid 304 stainless steel framework, ensuring a minimum thickness of 1 to 5 mm. |
| 2 |
Cremation Time |
30-90 minutes |
| 3 |
Furnace Specification |
The dimensions are 11.5 feet in length, 6 feet in width, and 6 feet in height. To move the body inside the furnace, we used a trolley made from SS304 material, which was loaded manually. |
| 4 |
Incinerating Chamber Dimensions |
Size: 08 ft(L) X 4.5 ft(W) X 4.5 ft(H) |
| 5 |
Wet Scrubber |
Advanced Three Stage De-carbonization filtration Technology, Ss304, 3mm thick plate, Height 12.5 ft with stand, diameter 3 ft. Completely made up of Stainless Steel 304 Grade. |
| 6 |
Door |
Front opening door 4ft x 3ft with hinges |
| 7 |
Temperature in Chamber |
Primary Chamber Temperature 750 degree C |
| 8 |
Machine Accessories |
Clean Out ports, packing support Grid, Strainer, Safety accessories, water level indicator, Inspection vent, Drain valve with ball valve, water controller valve. Thermocouple, Pressure Gauge, |
| 9 |
Civil Work |
As per Guidelines proposed and required by the authority |
| 10 |
Space Required |
30 X 30 ft for One Incinerator |
| 11 |
Blower (Optional) |
3 hp power supply with very high RPM |
| 12 |
Control Panel (Automatic) |
We supply one unit of scrubbing pumps ranging from 1.5 to 3 HP, along with one unit of ID fans that operate between 3 to 6 HP and come with timed control features. Additionally, an automatic control panel based on HMI and PLC, which also allows for manual operation, is required. Don't forget the sophisticated variable drives that utilize fans to help manage temperatures. |
| 13 |
ID Fan |
3-6 HP ID FAN FOR SUCTION OF SMOKE |
| 14 |
Scrubber Efficiency |
As per the guidelines of CPCB |
| 15 |
Burning Capacity |
150-200 kg per hour |
| 16 |
Operator |
Can be operated by semi-skilled/skilled labor |
| 17 |
Emission |
As per DPCC/CPCB |
| 18 |
Clean Outdoor |
Width maximum 5ft and height maximum Ift 5 inches |
| 19 |
Front door frame |
4 x 3.5 feet |
| 20 |
Advance HMI and PLC control |
Introducing a fully automatic digital PLC control panel that comes with a built-in machine to display all parameters. It features a user-friendly one-touch operation system with a vibrant 7-inch touchscreen. The HMI is also equipped with data recipes, event logging, and event triggering capabilities.
|
| 21 |
Operating Voltage |
415-440 V, 4.5-5 KW, 3 phase AC 50 C/S |
| 22 |
Chimney |
As per CPCB standards, the 10-meter self-supporting chimney will have a base diameter of 1200 mm, tapering to 324 mm and finally 22 mm. It will be secured using high-tension half-threaded bolts with one spring washer and two plain washers. Foundation bolts will be 32 mm in diameter and 900 mm long. The structure includes a 10 mm steel core wire rope, aircraft light, earthing strip plates, ladder with platform, lightning arrestor, and other necessary accessories. |